Hazardous location emergency lighting refers to a lighting system that continues to operate during power failures without igniting flammable gases, vapors, dust, or fibers in the vicinity. To identify the required luminaire, it is important to know the Class, Division, or Zone, Group, and temperature rating of the hazardous location where you are working. These classifications determine what kind of hazard is present in the area, how often it is expected to occur, and what level of protection against ignition is required.
Below, you can read about the basics of classification, their differences, and considerations for selecting appropriate emergency lights for hazardous locations, such as refineries, chemical plants, grain storage areas, paint booths, and fuel-handling areas.
Why Is Emergency Lighting Important in Hazardous Locations?
In the event of a failure of the regular power supply in hazardous environments, people need to be able to see to stop the processes, find the exit, and evacuate safely. Darkness in the area increases the risk of injuries, reaction delays, and secondary accidents. At the same time, any electrical equipment in the area is an ignition source that can lead to fire or explosion. This is why hazardous location emergency lighting must ensure two things at the same time: reliable lighting in the event of a blackout and certified protection against ignition. Standard emergency lights, no matter how reliable, are not designed for that purpose.
What Is a Hazardous Location?
A hazardous location, sometimes referred to as a classified area, is a place where flammable gases, combustible dust, or ignitable fibers are present in amounts that could cause a fire or explosion. In the USA, the National Electrical Code (NEC) regulates the classification and wiring of such places. The traditional Class and Division approach is covered in Article 500. Articles 505 and 506 cover the Zone approach that is closer to the international IEC standards.
It is the responsibility of the facility owner or safety manager to classify the area, in consultation with engineers and the authority having jurisdiction. After that, all electrical equipment to be used in the area should be approved.
Understanding the Class Classification
Class is the type of hazardous material that is in the atmosphere. There are three Classes of hazardous locations.
Class I: Flammable Gases and Vapors
Class I hazardous locations have gases or vapors that can ignite, such as gasoline, propane, hydrogen, or solvent fumes. The most typical Class I locations are refineries, fuel storage and dispensing areas, paint spray areas, and chemical plants.
Class II: Combustible Dust
Class II hazardous locations have combustible dust, such as grain, flour, sugar, coal, magnesium, or aluminum. Grain elevators, food processing plants, woodworking shops, and metal fabrication facilities are classified as Class II.
Class III: Ignitable Fibers and Flyings
Class III hazardous locations involve easily ignitable fibers or flying particles that are not likely to be suspended in the air but may collect around the equipment. The most common examples of Class III locations are textile mills, cotton gins, and wood processing facilities.
Division 1 vs. Division 2: How Often Is the Hazard Expected?
Within each class, the Division specifies how often the hazard appears.
- Division 1: The hazardous material is present under normal operating conditions, during frequent maintenance or repair, or in case of equipment failure and release of hazardous material at the same time as the electrical equipment failure.
- Division 2: The hazardous material is typically controlled or contained, except in abnormal conditions, such as container leaks, ventilation failure, or spills.
Division 1 requires the highest protection. Fixtures for Division 1 require explosion-proof equipment or other certified methods of protection from ignition. Division 2 allows a wider range of protection methods, but it still requires proper approvals.
Zone Classification Explanation
Zone classification is more precise in describing the hazard and distinguishes gas and vapor from dust. Zone classification is increasingly used in new buildings, international facilities, and projects that follow IEC and ATEX standards.
Gas and Vapor Zones: 0, 1, and 2
- Zone 0: Continuous presence of explosive gas atmosphere.
- Zone 1: Explosive gas atmosphere is likely to occur under normal operating conditions.
- Zone 2: Explosive gas atmosphere is not likely to occur under normal operating conditions and lasts only for a short time.
Dust Zones: 20, 21, and 22
- Zone 20: Continuous presence of combustible dust.
- Zone 21: Combustible dust is likely to occur under normal operating conditions.
- Zone 22: Combustible dust is not likely to occur under normal operating conditions and lasts only for a short time.
Class/Division vs. Zone Classification: Comparison
The two classification systems are similar but differ in how they describe the same hazards. Below is the comparison chart, though the classification should be made by a professional based on your particular situation.
| Hazard | Class/Division System | Zone System |
|---|---|---|
| Gases and vapors are present continuously or for long periods | Class I, Division 1 | Zone 0 |
| Gases and vapors, likely during normal operation | Class I, Division 1 | Zone 1 |
| Gases and vapors are present only during abnormal conditions | Class I, Division 2 | Zone 2 |
| Combustible dust, present continuously or for long periods | Class II, Division 1 | Zone 20 |
| Combustible dust, likely during normal operation | Class II, Division 1 | Zone 21 |
| Combustible dust is present only during abnormal conditions | Class II, Division 2 | Zone 22 |
Gas Groups and Temperature Codes
Apart from the Class and Division or Zone classifications, the equipment should match the Group and have the proper temperature code. In the Class/Division system, Class I involves Groups A (acetylene), B (hydrogen), C (ethylene), and D (propane, gasoline, and others). Class II includes Groups E (metal dusts), F (carbon-based dusts, such as coal), and G (grain, flour, and plastic dusts). Each Group corresponds to the ease of ignition and the energy required for it.
Temperature codes T1 to T6 indicate the fixture’s maximum surface temperature, which should remain below the ignition temperature of the surrounding hazardous material. Even if a fixture is completely sealed, it can be dangerous if its housing becomes too hot. LEDs are especially well-suited in this case because they operate at lower temperatures than old-fashioned metal-halide or incandescent sources.
Requirements for Emergency Lighting in Classified Areas
Hazardous location emergency lighting and exit signs are regulated by several layers of standards. In particular, the NEC specifies the installation requirements for classified areas. NFPA 101 and OSHA specify the requirements for emergency egress lighting that should provide illumination for at least 90 minutes after a power failure. Other requirements may apply locally.
The fixture should be certified by a third-party that is a recognized testing laboratory. In North America, UL 844 specifies luminaires for hazardous locations, and UL 924 covers emergency lighting and power equipment. Check product labels for the Class, Division or Zone, Group, and temperature code.
How to Select Hazardous Location Emergency Lights
Determine Your Area Classification
Begin by finding the documents about the classification of your hazardous area. If the documents are outdated or lost, you need to classify the area before installing any equipment. Changes in process, new materials, or improved ventilation might change your classification.
Match the Rating of Your Fixtures
Choose the luminaires with the necessary Class, Division, or Zone, Group, and temperature code corresponding to your project needs. A luminaire approved for Class I, Division 2 cannot be used in a Class I, Division 1 area.
Consider the Source of the Power Supply
You should consider whether the fixture has an internal battery backup system, a remote battery, an inverter system, or a generator as a power source. It is especially important to know about battery location because the batteries and charging systems should also be suitable for the classified area.
Consider the Environment
Corrosive chemicals, washdown processes, extreme temperatures, vibrations, and outdoor conditions affect the choice of housing material and its ingress protection. A corrosion-resistant finish and a sealed lens increase the fixture’s lifetime and help preserve the explosion-proof enclosure.
Plan the Maintenance
Emergency lights should work reliably when they are needed. Monthly and annual tests should be included in the safety program, and the fixtures should allow easy battery maintenance without breaking the hazardous location seal.
Common Mistakes to Avoid
- Installing standard emergency lights in hazardous areas. Standard fixtures do not have the necessary tests for explosive atmospheres.
- Mixing Division and Zone ratings. Verify the equivalency instead of assuming it.
- Ignoring temperature codes. Surface temperature is the major ignition factor.
- Forgetting about possible field modifications. Drilling, rewiring, or modification of the fixture might void its certification.
- Not inspecting the fixture regularly. Damaged seals, cracked lenses, and loose fittings reduce the fixture’s protection.
Frequently Asked Questions
What is the difference between Class I, Class II, and Class III locations?
Class I locations contain flammable gases or vapors, Class II locations contain combustible dust, and Class III locations contain ignitable fibers or flyings.
What is the difference between Division 1 and Division 2?
In Division 1, the hazard is present under normal operating conditions, and in Division 2, it is present only under abnormal conditions, such as leakage or equipment failure.
Is Zone 1 the same as Division 1?
Not exactly. Zone 1 corresponds to a certain portion of Division 1, while Zone 0 and Zone 1 are considered the same as Class I, Division 1. Though the classification systems are related, they are not interchangeable. Always verify the fixture ratings against your real classification.
Can I use standard LED emergency lights in hazardous locations?
No. Only luminaires with proper Class, Division, or Zone, Group, and temperature code certifications may be used. Standard LED fixtures are not tested for protection against ignition in explosive atmospheres.
How long should hazardous location emergency lights operate in case of power failure?
Life safety codes, such as NFPA 101, require that emergency egress lighting operate for at least 90 minutes. The final decision is up to your local code and authority having jurisdiction.
Light the Way with Isolite
Class, Division, and Zone basics are the first step towards safety in hazardous locations. Proper hazardous-location emergency lighting will keep your people safe during a blackout and help prevent ignition. To find fixtures that meet your area classification, contact the Isolite team.
- Hazardous location LED lighting link from the sections on classified areas and temperature codes
- Explosion-proof lighting link from the Division 1 vs. Division 2 section
- Emergency lighting products link from the emergency lighting requirements section
- Contact Isolite / request a quote link from the conclusion